Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 15,0 gypsum plaster board type DF 0,250 10 800 1,050 A2
A 15,0 gypsum fibre board or 0,320 21 1000 1,100 A2
B 8,0 Funderplan Biofaser 0,180 185 1000 1,700 D
C 100,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
D - variable insulation material
E 8,0 Funderplan Biofaser 0,180 185 1000 1,700 D
F 15,0 gypsum plaster board type DF 0,250 10 800 1,050 A2
F 15,0 gypsum fibre board or 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
iwrxxo16a-00 D 100,0 Cellulose fibre [039; 50] 146,0 60 43 (-1,-5) 16,39 48,8
iwrxxo16a-01 D 100,0 Wood fibre insulation [039; 45] 146,0 60 43 (-1,-5) 17,18 48,4
iwrxxo16a-02 D 100,0 mineral wool [040; ≥16; <1000°C] 146,0 60 43 (-1,-5) 19,85 45,8

Source: FunderMax GmbH

Last update 20.06.2024/hfa.plb