Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 90
maximum ceiling height = 3 m; maximum load Ed,fi = 19kN/m  
Classified by HFA  
Thermal performance U
Diffusion
Acoustic performance Rw (C;Ctr) 63 dB
Ln,w (Cl)
The acoustic insulation assessment is based on a length-related flow resistance of r≥5 kPa.s/m². If this value is lower for the insulation material used, the Rw value is reduced by 3dB.  
Rating by TGM  
Mass per unit area m 93,0 kg/m2
 

data sheet internal wall
iwrxxi02b-02 (pdf, 250 KB)

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 30,0 Rigips Riduro 2x... mm 0,250 4-10 1000 1,050 A2
B 120,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
C 120,0 ISOVER Ultimate 0,035 1 20 1,030 A1
D 30,0 Rigips Riduro 2x.. 0,250 4-10 1000 1,050 A2
E 50,0 RigiProfil >50mm; resilient channel
F 50,0 mineral wool [040; 11; <1000°C] 0,040 1 11 1,030 A1
G 25,0 Rigips Duo Tech 0,250 4-10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 9,6 kg
Share of renewable materials of total weight 10,41 %
Global warming potential (GWP-T) 16,056 kgCO2Äqv.
Energy use of Primary Energy 531,2 MJ
Share of renewable Primary Energy 9,4 %
∑ΔOI3 32,3
Calculated by IBO  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 29,029 -12,974 16,056 49,720 139,286 189,006 481,432 2,056 483,488 0,101 0,048 3.2277371E-6 0,015

Source: Saint-Gobain Austria GmbH

Last update 02.08.2023/hfa.eco2soft