Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 30
maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m
Classified by MA39  
Classified by HFA  
Thermal performance U
Diffusion
Acoustic performance Rw (C;Ctr)
Ln,w (Cl)
Mass per unit area m 25,5 kg/m2
Calculation based on gypsum plaster board type DF GF
 

Datenblatt internal wall
iwrxxo01a-00 (pdf, 250 KB)

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2
A 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
B 100,0 construction timber (60/100 or 60/160; e=*) 0,120 50 450 1,600 D
C 100,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
D 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2
D 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 11,4
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 1,087 0,041 0,019 1,13e-6 0,003 12,521 92,514 105,035 166,836 3,484 170,320

Last update 07.05.2020/hfa.plb