Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 60
maximum ceiling height = 3 m; maximum load Ed,fi = 50,0 kN/m
Classified by MA39  
Thermal performance U
Diffusion
Acoustic performance Rw (C;Ctr)
Ln,w (Cl)
Mass per unit area m 47,0 kg/m2
Calculation based on gypsum plaster board type DF GF
 

Datenblatt internal wall
iwrxxo01b-03 (pdf, 250 KB)

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
A 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2
B 100,0 construction timber (60/100 or 60/160; e=*) 0,120 50 450 1,600 D
C 100,0 mineral wool [038; ≥33; ≥1000°C] 0,038 1 33 1,030 A1
D 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
D 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

OI3Kon -16,4
Calculated by IBO  

GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
PEI ne
[MJ]
PEI e
[MJ]
EP
[kg PO4 Äqv.]
POCP
[kg C2H4 Äqv.]
8,3 0,069 280,4 124,3 0,012 0,014