Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 60
maximum ceiling height = 3 m; maximum load Ed,fi = 50 kN/m
Classified by HFA  
Fire performance Germany
Classification: F30/F60 (depending on the corresponding proof)  
Load Ed,fi according to the German certification document
Proof: F30: DIN 4102-4:2016-05, Tabelle 10.5,Zeile 5; F60: DIN 4102-4:2016-05, Tablle 10.5, Zeile 10 (if gypsum plaster board type DF or gypsum fibre board 15 mm inside) or manufacturer-specific  
Thermal performance U
Diffusion
Acoustic performance Rw (C;Ctr) 43 dB (-1; -5)
Ln,w (Cl)
Assessed by Müller-BBM  
Mass per unit area m 48,4 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

Datenblatt internal wall
iwrxxo01b-08 (pdf, 250 KB)

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
A 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2
B 100,0 construction timber (60/100 or 60/160; e=*) 0,120 50 450 1,600 D
C 100,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
D 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
D 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 10,6 kg
Biogenic carbon 14,3 kgCO2 Äqv.
Energy use of Primary Energy 246,8 MJ
Share of renewable PE 19,7 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000
C1 - C4 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000
A1 - C4 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000

Last update 19.04.2018/hfa.plb