Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 90
maximum ceiling height = 3 m; maximum load Ed,fi = 23,4 kN/m  
Classified by HFA  
Thermal performance U
Diffusion
Acoustic performance Rw (C;Ctr) 43 dB
Ln,w (Cl)
The acoustic insulation assessment is based on a length-related flow resistance of r≥5 kPa.s/m². If this value is lower for the insulation material used, the Rw value is reduced by 3dB.  
Rating by TGM  
Mass per unit area m 59,9 kg/m2
 

data sheet internal wall
iwrxxo08b-01 (pdf, 250 KB)

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 25,0 Rigips Riduro 2*12,5mm 0,250 4-10 1000 1,050 A2
B 120,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
C 120,0 Hemp insulation [040; 30] 0,040 1-2 30 2,200 E
D 25,0 Rigips Riduro 2*12,5mm 0,250 4-10 1000 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 11,5 kg
Share of renewable materials of total weight 19,24 %
Global warming potential (GWP-T) -1,611 kgCO2Äqv.
Energy use of Primary Energy 292,2 MJ
Share of renewable Primary Energy 11,2 %
∑ΔOI3 14,6
Calculated by IBO  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 16,250 -17,861 -1,611 32,873 194,467 227,340 259,370 5,919 265,290 0,045 0,021 1.8171098E-6 0,008

Source: Saint-Gobain Austria GmbH

Last update 02.08.2023/hfa.eco2soft