Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 60
maximum ceiling height = 3 m; maximum load Ed,fi = 32 kN/m  
Classified by HFA  
Thermal performance U
Diffusion
Calculated by HFA  
Acoustic performance Rw (C;Ctr)
Ln,w (Cl)
Rating by HFA  
Mass per unit area
 

data sheet internal wall
iwrxxo11a-01 (pdf, 250 KB)

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 16,0 Kronospan OSB-Firestop 0,110 150-170 660 1,700 B
B 140,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
C 140,0 mineral wool [038; ≥33; ≥1000°C] 0,038 1 33 1,030 A1
D 16,0 Kronospan OSB-Firestop 0,110 150-170 660 1,700 B

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 25,7 kg
Share of renewable materials of total weight 79,79 %
Global warming potential (GWP-T) -24,342 kgCO2Äqv.
Energy use of Primary Energy 357,9 MJ
Share of renewable Primary Energy 20,7 %
∑ΔOI3 21,1
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 18,861 -43,202 -24,342 73,977 449,053 523,030 283,875 25,055 308,930 0,112 0,036 1.2049933E-6 0,038

Source: KRONOSPAN OSB, spol. s r. o.

Last update 02.08.2023/hfa.eco2soft