external wall solid wood construction, ventilated, with dry lining, with cladding
| Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
|---|---|---|---|---|---|---|---|
| λ | μ min – max | ρ | c | ||||
| A | 19,0 | larch wood external wall cladding, e.g. clapboard facade | 0,120 | 50 | 450 | 1,600 | D |
| B | 40,0 | spruce wood ventilation | 0,120 | 50 | 450 | 1,600 | D |
| C | wind barrier (building papers) | 1000 | |||||
| D | 24,0 | planking spruce wood diagonal formwork | 0,120 | 50 | 450 | 1,600 | D |
| E | 280,0 | construction timber (60/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
| F | - variable insulation material | ||||||
| G | 100,0 | cross laminated timber 5-ply (top layer at least 20 mm) joints airtight | 0,130 | 50 | 500 | 1,600 | D |
| H | 30,0 | spruce wood battens vertical / air layer | 0,120 | 50 | 450 | 1,600 | D |
| I | 22,0 | clay board | 0,353 | 5-10 | 1450 | 1,100 | A1 |
| J | 5,0 | 0,810 | 10 | 1700 | 0,930 | A1 | |
| Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] | ||
Last update 05.08.2024/hfa.plb