Skip to main content
Regional validity

Scope

solid wood construction
Cross-section of standard configuration

Note

ATTENTION: Pay attention to the plasterboard fastening and execution of the joints according to the classification report!

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B - variable building material
C 15,0 gypsum fibre board or 0,320 21 1000 1,100 A2
C 15,0 gypsum plaster board type DEF (for exterior panelling acc. to EN 520) 0,250 10 900 1,050 A2
D 100,0 cross laminated timber 0,130 50 500 1,600 D
E 30,0 gypsum plaster board type DF (2x15 mm) or 0,250 10 800 1,050 A2
E 30,0 gypsum fibre board (2x15 mm) 0,320 21 1000 1,100 A2
F 50,0 CW profile freestanding
G 50,0 mineral wool [0,35; ≥20; <1000^C] 0,035 1 20 1,030 A1
H 15,0 gypsum plaster board type DF or 0,250 10 800 1,050 A2
H 15,0 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awmopi06b-00 B 120,0 MW-PT [035; 90; ≥1000°C] 337,0 90 from inside
90 from outside
0,18 adequate 57 (-7,-13) 55,05 127,4

Last update 13.01.2025/hfa.plb