Regional validity

Scope

timber frame construction
Cross-section of standard configuration

Note

ATTENTION: Pay attention to the plasterboard fastening and execution of the joints according to the classification report!

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood facade 0,120 50 450 1,600 D
B 30,0 spruce wood vertical battens (≥ 30/50 mm) ventilation 0,120 50 450 1,600 D
C wind barrier 1000
D 60,0 spruce wood horizontal battens (≥ 40 / 60 mm) 0,120 50 450 1,600 D
E 60,0 mineral wool [035; ≥50; ≥1000°C] 0,035 1 50 1,030 A1
F 30,0 gypsum fibre board (2x15mm) or 0,320 21 1000 1,100 A2
F 30,0 gypsum plaster board type DEF (for exterior panelling acc. to EN 520) (2x15mm) 0,250 10 900 1,050 A2
G 160,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
H - variable insulation material
I vapour barrier sd≥ 4m 1000
J 30,0 gypsum plaster board type DF (2x15mm) or 0,250 10 800 1,050 A2
J 30,0 gypsum fibre board (2x15 mm) 0,320 21 1000 1,100 A2
K 50,0 CW profile freestanding
L 50,0 mineral wool [0,35; ≥20; <1000^C] 0,035 1 20 1,030 A1
M 15,0 gypsum plaster board type DF or 0,250 10 800 1,050 A2
M 15,0 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awrhhi21b-00 H 160,0 mineral wool [0,35; ≥20; <1000^C] 399,0 90 from inside
90 from outside
0,15 adequate 64 (-5,-13) 60,58 95,2

Last update 13.01.2025/hfa.plb