Skip to main content
Regional validity

Scope

solid wood construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 160,0 wooden grating/wooden terrace mounted on adjustable feet on a sound-insulated base 0,130 50 500 1,600 D
B 80,0 gravel between the levelling feet 0,700 1 1800 1,000 A1
C separation nonwoven
D 1,8 sealing sheet sd≥ 100m eg EPDM
E (sliding/separating layer)
F 30,0 impact sound absorbing subflooring MW-T [s' = 40MN/m³] 0,040 1 160 0,840 A2
G - variable insulation material laid on a slope
H 0,230 1100 E
I 150,0 cross laminated timber 5-ply (first layer mind. 30mm) 0,130 50 500 1,600 D

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
fdmoko01-00 G 360,0 60 0,10 adequate 51 (-1,-5) 209,21 293,2
fdmoko01-01 G 260,0 60 0,10 adequate 51 (-1,-5) 115,68 253,5

Last update 05.08.2024/hfa.plb