Scope

solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A sheet metal roofing structured separation layer 7800 A1
B 24,0 spruce wood formwork 0,120 50 450 1,600 D
C 80,0 spruce wood counter battens (40/80) 0,120 50 450 1,600 D
D sarking membrane sd ≤ 0,3m 1000 E
E 24,0 planking spruce wood full formwork 0,120 50 450 1,600 D
F construction timber (80/..; e=800) 0,120 50 450 1,600 D
G Cellulose fibre [040; 50] 0,040 1 50 2,000 E
H 0,2 sealing sheet (air tight)
I 120,0 cross laminated timber 0,130 50 500 1,600 D
J 60,0 spruce wood (battens 60/60; e=400) 0,120 50 450 1,600 D
K 60,0 mineral wool [040; 11; <1000°C] 0,040 1 11 1,030 A1
L 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
sdmhbi02a-00 F
G
180,0
180,0
construction timber
Cellulose fibre [040; 50]
500,5 60 0,15 adequate 48 (-1,-6) 42,76 119,1
sdmhbi02a-01 F
G
200,0
200,0
construction timber
Cellulose fibre [040; 50]
520,5 60 0,14 adequate 49 (-1,-6) 43,14 120,9
sdmhbi02a-02 F
G
240,0
240,0
construction timber
Cellulose fibre [040; 50]
540,5 60 0,13 adequate 50 (-1,-6) 43,91 124,5