Skip to main content
Regional validity

Scope

solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A concrete roof tile /tiled roof 2100 A1
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C 50,0 spruce wood counter battens (minimum height 50 mm) 0,120 50 450 1,600 D
D - variable building material
E - variable insulation material insulation placed on top of the rafters
F sealing sheet
G 100,0 cross laminated timber BBS 125 5 layer 0,130 50 470 1,600 D
H 70,0 spruce wood battens (60/60; e=625) mounted on resilient clips 0,120 50 450 1,600 D
I 50,0 mineral wool [040; 18] 0,040 1 18 1,030 A1
J 30,0 gypsum plaster boards Rigips RF (2x15 mm) or 0,250 10 900 1,050 A2
J 30,0 gypsum fibre board Rigidur H (2x15 mm) 0,350 19 1200 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) ΔOI3 m [kg/m²]
sdmhzi01b-00 D
E
22,0
200,0
softboard [047; 200]
softboard [040; 110]
502,0 90 0,13 adequate 66 (-7,-15) 60,40 189,5
sdmhzi01b-01 D
E
22,0
240,0
softboard [047; 200]
softboard [040; 110]
522,0 90 0,11 adequate 66 (-7,-15) 64,97 193,9
sdmhzi01b-02 D
E

180,0
sarking membrane sd ≤ 0,3m
Aufsparren-Dämmplatte Isover Integra AP Solid Black
460,0 90 0,13 adequate 64 (-5,-13) 98,96 181,2
sdmhzi01b-03 D
E

200,0
sarking membrane sd ≤ 0,3m
Aufsparren-Dämmplatte Isover Integra AP Solid Black
480,0 90 0,12 adequate 64 (-5,-13) 98,96 183,2

Source: Saint-Gobain Austria GmbH

Last update 07.07.2021/hfa.plb