pitched roof timber frame construction, ventilated, with dry lining, not suspended
The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | concrete roof tile or tiled roof | 2100 | A1 | ||||
B | 30,0 | spruce wood battens (30/50) | 0,120 | 50 | 450 | 1,600 | D |
C | 50,0 | spruce wood counter battens (minimum height 50 mm) | 0,120 | 50 | 450 | 1,600 | D |
D | 22,0 | softboard [045; 250] - rigid underlay | 0,045 | 5 | 250 | 2,100 | E |
E | construction timber (80/..; e=800) | 0,120 | 50 | 450 | 1,600 | D | |
F | - variable insulation material | ||||||
G | vapour barrier sd≥ 1m | 1000 | |||||
H | 24,0 | spruce wood cladding with spacing of cladding boards(24/100); a=400 | 0,120 | 50 | 450 | 1,600 | D |
I | 12,5 | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 |
I | 12,5 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] |
Last update 02.08.2023/nu.ge