Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A concrete roof tile or tiled roof 2100 A1
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C 50,0 spruce wood counter battens (minimum height 50 mm) 0,120 50 450 1,600 D
D 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
E construction timber (80/..; e=800) 0,120 50 450 1,600 D
F - variable insulation material
G vapour barrier sd≥ 1m 1000
H spruce wood cross battens (50/80;a=400) 0,120 50 450 1,600 D
I - variable building material
J 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
J 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
sdrhzi08b-00 E
F
H
I
200,0
200,0
50,0
50,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
370,0 60 0,18 adequate 53 (-3,-9) 33,10 47,6
sdrhzi08b-01 E
F
H
I
200,0
200,0
50,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
air layer
370,0 I=without insulation 60 0,21 adequate 50 (-4,-10) 30,27 47,0
sdrhzi08b-02 E
F
H
I
220,0
220,0
50,0
50,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
390,0 60 0,17 adequate 53 (-2,-8) 34,33 48,9
sdrhzi08b-03 E
F
H
I
240,0
240,0
50,0
50,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
410,0 60 0,16 adequate 54 (-2,-9) 35,56 50,2
sdrhzi08b-04 E
F
H
I
200,0
200,0
50,0
50,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
370,0 60 0,16 adequate 54 (-3,-9) 60,72 55,1
sdrhzi08b-05 E
F
H
I
200,0
200,0
50,0
50,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
370,0 60 0,18 adequate 53 (-2,-8) 40,23 51,4
sdrhzi08b-06 E
F
H
I
200,0
200,0
50,0
50,0
construction timber
cellulose fibre [040; E]
spruce wood
cellulose fibre [040; E]
370,0 60 0,18 adequate 54 (-3,-9) 24,68 56,2
sdrhzi08b-07 E
F
H
I
200,0
200,0
50,0
50,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
370,0 60 0,20 adequate 53 (-4,-10) 25,69 47,6

Last update 02.08.2023/hfa.eco2soft