pitched roof exposed rafter, ventilated, -, without lining
The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | concrete roof tile or tiled roof | 2100 | A1 | ||||
B | 30,0 | spruce wood battens (30/50) | 0,120 | 50 | 450 | 1,600 | D |
C | 50,0 | spruce wood counter battens (Austria: minimum height 50 mm), Germany 30 mm | 0,120 | 50 | 450 | 1,600 | D |
D | 22,0 | softboard [045; 250] - rigid underlay | 0,045 | 5 | 250 | 2,100 | E |
E | - variable insulation material - insulation placed on top of the rafters | ||||||
F | vapour barrier sd≥ 1m | 1000 | |||||
G | 40,0 | spruce wood tongue and groove, fire protection cladding (Germany minimum 50 mm) | 0,120 | 50 | 450 | 1,600 | D |
H | construction timber in acc. with structural design | 0,120 | 50 | 450 | 1,600 | D |
Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] | ||
sdshzx01-00 | E | 180,0 | mineral wool [040; 180; ≥1000°C] | 322,0 | 30 | 0,18 | adequate | 42 (-3,-8) | 84,26 | 121,9 |
sdshzx01-01 | E | 180,0 | wood-fibre insulation board [0,040; R=200] | 322,0 | 30 | 0,18 | adequate | 42 (-3,-8) | 41,40 | 125,5 |
sdshzx01-04 | E | 240,0 | mineral wool [040; 180; ≥1000°C] | 382,0 | 30 | 0,14 | adequate | 44 (-3,-8) | 107,45 | 132,7 |
sdshzx01-05 | E | 240,0 | wood-fibre insulation board [0,040; R=200] | 382,0 | 30 | 0,14 | adequate | 44 (-3,-8) | 50,30 | 137,5 |
Last update 02.08.2023/hfa.eco2soft