pitched roof timber frame construction, ventilated, with dry lining, not suspended
Fire performance | REI | 30 |
---|---|---|
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m² (rafter 80/200 without roofing, full formwork and counter battens)
Classified by HFA
Fire performance Germany
Classification: F30
Load Ed,fi according to the German certification document
Proof: DIN 4102-4:2016-05, Tabelle 10.19, Zeile 1
|
||
Thermal performance | U | 0,16 W/(m2K) |
Diffusion | adequate | |
Calculated by TUM
|
||
Acoustic performance | Rw (C;Ctr) | 51 dB (-4; -11) |
Ln,w (Cl) | ||
Rating by Müller-BBM
|
||
Mass per unit area | m | 53,5 kg/m2 |
data sheet pitched roof
sdrhbi01a-03 (pdf, 250 KB)
The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | sheet metal roofing on structured separation layer | 7800 | A1 | ||||
B | 24,0 | spruce wood full formwork | 0,120 | 50 | 450 | 1,600 | D |
C | 80,0 | spruce wood counter battens (40/80) | 0,120 | 50 | 450 | 1,600 | D |
D | sarking membrane sd ≤ 0,3m | 1000 | E | ||||
E | 24,0 | planking spruce wood full formwork | 0,120 | 50 | 450 | 1,600 | D |
F | 240,0 | construction timber (80/*; e=625) | 0,120 | 50 | 450 | 1,600 | D |
G | 240,0 | mineral wool [040; 11; <1000°C] | 0,040 | 1 | 11 | 1,030 | A1 |
H | vapour barrier sd≥ 10m | 1000 | |||||
I | 30,0 | spruce wood cross battens (a=400) | 0,120 | 50 | 450 | 1,600 | D |
J | 30,0 | mineral wool [040; 11; <1000°C] | 0,040 | 1 | 11 | 1,030 | A1 |
K | 12,5 | gypsum plaster board type DF | 0,250 | 10 | 800 | 1,050 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 26,881 | -63,776 | -36,895 | 115,275 | 662,244 | 777,519 | 433,744 | 12,683 | 446,427 | 0,139 | 0,066 | 2.1593373E-6 | 0,031 |
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP [kgCO2Äqv.] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
A1 - A3 | -34,599 | 0,159 | 0,023 | 1.39E-6 | 0,020 | 226,011 | 767,827 | 997,124 | 485,450 | 92,054 | 577,652 |
C1 - C4 | 73,792 | 0,003 | 0,003 | 1.3E-7 | 0,000 | 0,563 | -761,454 | -760,891 | 13,337 | -0,159 | 13,178 |
A1 - C4 | 42,169 | 0,163 | 0,026 | 1.53E-6 | 0,021 | 226,963 | 6,632 | 236,881 | 505,375 | 91,947 | 597,470 |
Last update 02.08.2023/nu.ge