Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 30
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Classified by IBS  
Thermal performance U 0,20 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 49 dB (-5; -11)
Ln,w (Cl)
with a tiled roof Rw = 47 (-5; -11) dB  
Assessed by TGM  
Mass per unit area m 33,5 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

Datenblatt pitched roof
sdrhzi03a-01 (pdf, 250 KB)

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A concrete roof tile or tiled roof 2100 A1
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C 50,0 spruce wood counter battens (minimum height 50 mm) 0,120 50 450 1,600 D
D 22,0 softboard [045; 250] - rigid underlay 0,045 5 250 2,100 E
E 200,0 construction timber (80/..; e=800) 0,120 50 450 1,600 D
F 200,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
G vapour barrier sd≥ 1m 1000
H 50,0 spruce wood cross battens (50/80;a=400) 0,120 50 450 1,600 D
I air layer 1 1 1,008
J 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
J 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 26,6
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -13,553 0,114 0,049 2,64e-6 0,007 38,102 426,948 465,050 392,302 14,722 407,024

Last update 07.05.2020/hfa.plb