Building physical assessment

Fire performance REI 60
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Classified by HFA  
Thermal performance U 0,15 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 54 dB (-4; -10)
Ln,w (Cl)
with a tiled roof Rw = 51 (-4; -10) dB  
Rating by TGM  
Mass per unit area m 51,6 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet pitched roof
sdrhzi03b-04 (pdf, 250 KB)

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A concrete roof tile or tiled roof 2100 A1
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C 50,0 spruce wood counter battens (minimum height 50 mm) 0,120 50 450 1,600 D
D 22,0 softboard [045; 250] - rigid underlay 0,045 5 250 2,100 E
E 200,0 construction timber (80/..; e=800) 0,120 50 450 1,600 D
F 200,0 mineral wool [035; 50; <1000°C] 0,035 1 50 1,030 A1
G vapour barrier sd≥ 1m 1000
H 50,0 spruce wood cross battens (50/80;a=400) 0,120 50 450 1,600 D
I 50,0 mineral wool [035; 50; <1000°C] 0,035 1 50 1,030 A1
J 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
J 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 25,4 kg
Share of renewable materials of total weight 25,96 %
Global warming potential (GWP-T) 7,510 kgCO2Äqv.
Energy use of Primary Energy 889,1 MJ
Share of renewable Primary Energy 10,4 %
∑ΔOI3 58,8
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 48,583 -41,074 7,510 92,725 418,991 511,715 796,368 12,980 809,348 0,229 0,106 4.9070977E-6 0,034

Last update 02.08.2023/hfa.eco2soft