pitched roof timber frame construction, ventilated, with dry lining, not suspended
Fire performance | REI | 30 |
---|---|---|
maximum span = 5 m; maximum load Ed,fi = 2,62 kN/m²
Classified by HFA
|
||
Thermal performance | U | 0,18 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 53 dB (-3; -9) |
Ln,w (Cl) | ||
with a tiled roof Rw = 52 dB
Rating by TGM
|
||
Mass per unit area | m | 59,1 kg/m2 |
Calculation based on gypsum plaster board type DF GKF
|
data sheet pitched roof
sdrhzi06a-06 (pdf, 250 KB)
The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | concrete roof tile or tiled roof | 2100 | A1 | ||||
B | 30,0 | spruce wood battens (30/50) | 0,120 | 50 | 450 | 1,600 | D |
C | 50,0 | spruce wood counter battens (minimum height 50 mm) | 0,120 | 50 | 450 | 1,600 | D |
D | sarking membrane sd ≤ 0,3m | 1000 | E | ||||
E | 24,0 | planking spruce wood closed cladding without spacing of cladding boards | 0,120 | 50 | 450 | 1,600 | D |
F | 200,0 | construction timber (80/..; e=800) | 0,120 | 50 | 450 | 1,600 | D |
G | 200,0 | cellulose fibre [0,040; R=55] | 0,040 | 1-2 | 55 | 2,000 | B |
H | 15,0 | OSB (sealed with airtight tape) | 0,130 | 200 | 600 | 1,700 | D |
I | 50,0 | spruce wood cross battens (50/80;a=400) | 0,120 | 50 | 450 | 1,600 | D |
J | 50,0 | cellulose fibre [0,040; R=55] | 0,040 | 1-2 | 55 | 2,000 | B |
K | 12,5 | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 |
K | 12,5 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 28,009 | -76,666 | -48,657 | 129,648 | 795,188 | 924,836 | 375,244 | 17,244 | 392,489 | 0,116 | 0,051 | 2.4849655E-6 | 0,025 |