Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 30
maximum span = 5 m; maximum load Ed,fi = 2,62 kN/m²  
Classified by HFA  
Thermal performance U 0,18 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 53 dB (-3; -9)
Ln,w (Cl)
with a tiled roof Rw = 52 dB  
Rating by TGM  
Mass per unit area m 59,1 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet pitched roof
sdrhzi06a-06 (pdf, 250 KB)

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A concrete roof tile or tiled roof 2100 A1
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C 50,0 spruce wood counter battens (minimum height 50 mm) 0,120 50 450 1,600 D
D sarking membrane sd ≤ 0,3m 1000 E
E 24,0 planking spruce wood closed cladding without spacing of cladding boards 0,120 50 450 1,600 D
F 200,0 construction timber (80/..; e=800) 0,120 50 450 1,600 D
G 200,0 cellulose fibre [0,040; R=55] 0,040 1-2 55 2,000 B
H 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
I 50,0 spruce wood cross battens (50/80;a=400) 0,120 50 450 1,600 D
J 50,0 cellulose fibre [0,040; R=55] 0,040 1-2 55 2,000 B
K 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
K 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 50,1 kg
Share of renewable materials of total weight 48,32 %
Global warming potential (GWP-T) -48,657 kgCO2Äqv.
Energy use of Primary Energy 504,9 MJ
Share of renewable Primary Energy 25,7 %
∑ΔOI3 20,4
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 28,009 -76,666 -48,657 129,648 795,188 924,836 375,244 17,244 392,489 0,116 0,051 2.4849655E-6 0,025

Last update 02.08.2023/hfa.eco2soft