Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 30
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Classified by HFA  
Thermal performance U 0,18 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 53 dB (-3; -9)
Ln,w (Cl)
with a tiled roof Rw = 51 (-3; -9) dB  
Rating by TGM  
Mass per unit area m 46,2 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet pitched roof
sdrhzi08a-06 (pdf, 250 KB)

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A concrete roof tile or tiled roof 2100 A1
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C 50,0 spruce wood counter battens (minimum height 50 mm) 0,120 50 450 1,600 D
D 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
E 200,0 construction timber (80/..; e=800) 0,120 50 450 1,600 D
F 200,0 cellulose fibre [040; E] 0,040 1-2 55 2,000 E
G vapour barrier sd≥ 1m 1000
H 50,0 spruce wood cross battens (50/80;a=400) 0,120 50 450 1,600 D
I 50,0 cellulose fibre [040; E] 0,040 1-2 55 2,000 E
J 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
J 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 39,1 kg
Share of renewable materials of total weight 42,15 %
Global warming potential (GWP-T) -30,618 kgCO2Äqv.
Energy use of Primary Energy 440,2 MJ
Share of renewable Primary Energy 19,1 %
∑ΔOI3 22,4
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 27,022 -57,640 -30,618 84,047 599,275 683,322 356,153 46,624 402,777 0,105 0,045 2.107787E-6 0,019

Last update 02.08.2023/hfa.eco2soft