Building physical assessment

Fire performance REI 60
Classified by HFA  
Thermal performance U 0,12 W/(m2K)
Diffusion adequate
Calculated by IBO  
Acoustic performance Rw (C;Ctr) 52 dB (-2; -8)
Ln,w (Cl)
Rating by HFA  
Mass per unit area m 105,2 kg/m2
 

data sheet pitched roof
sdrhzi12b-01 (pdf, 250 KB)

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 15,0 or tiled roof 2000 A1
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C 50,0 spruce wood counter battens (minimum height 50 mm) 0,120 50 450 1,600 D
D sarking membrane sd ≤ 0,3m 1000 E
E 24,0 planking spruce wood closed cladding without spacing of cladding boards 0,120 50 450 1,600 D
F 260,0 construction timber (80/..; e=800) 0,120 50 450 1,600 D
G 260,0 sheep wool [040; 30] 0,040 1 30 1,720 E
H 19,0 (sealed with airtight tape) 0,120 50-150 475 1,600 D
I vapour barrier sd≥ 6m 1000
J 100,0 spruce wood cross battens (50/80;a=400) 0,120 50 450 1,600 D
K 100,0 sheep wool [040; 30] 0,040 1 30 1,720 E
L 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
L 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 53,7 kg
Share of renewable materials of total weight 51,03 %
Global warming potential (GWP-T) -42,122 kgCO2Äqv.
Energy use of Primary Energy 687,0 MJ
Share of renewable Primary Energy 16,1 %
∑ΔOI3 29,8
Calculated by IBO  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 44,226 -86,347 -42,122 110,361 939,815 1050,176 576,593 15,069 591,663 0,128 0,059 3.6672018E-6 0,035

Last update 05.08.2024/hfa.plb