Building physical assessment

Fire performance REI 60
maximum span = 5 m; maximum load Ed,fi = 3,66 kN/m²  
Classified by HFA  
Thermal performance U 0,18 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 52 dB (-1; -7)
Ln,w (Cl)
with a tiled roof Rw = 50 (-1; -7) dB  
Rating by TGM  
Mass per unit area m 53,5 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet pitched roof
sdrhzo02b-02 (pdf, 250 KB)

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Only for registered members after logging in.
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A concrete roof tile or tiled roof 2100 A1
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C 50,0 spruce wood counter battens (minimum height 50 mm) 0,120 50 450 1,600 D
D sarking membrane sd ≤ 0,3m 1000 E
E 12,0 OSB 0,130 200 600 1,700 D
F 240,0 construction timber (80/..; e=800) 0,120 50 450 1,600 D
G 240,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
H vapour barrier sd≥ 11m 1000
I 15,0 OSB 0,130 200 600 1,700 D
J 25,0 gypsum plaster board type DF (2x12,5 mm) or 0,250 10 800 1,050 A2
J 25,0 gypsum fibre board (2x12,5 mm) 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 32,4 kg
Share of renewable materials of total weight 32,81 %
Global warming potential (GWP-T) -18,714 kgCO2Äqv.
Energy use of Primary Energy 639,8 MJ
Share of renewable Primary Energy 17,7 %
∑ΔOI3 34,1
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 34,143 -52,857 -18,714 113,018 543,379 656,397 526,785 25,917 552,702 0,141 0,064 3.3122894E-6 0,026

Last update 02.08.2023/hfa.eco2soft