Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 30
maximum span = 5 m; maximum load Ed,fi = 5,29 kN/m² (with exposed beams 180/240 and fire protection cladding)
Classified by IBSm²  
Classified by HFA  
Thermal performance U 0,13 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 44 dB (-2; -8)
Ln,w (Cl)
with a tiled roof Rw = 43 (-2; -8) dB
Assessed by TGM  
Mass per unit area m 77,6 kg/m2
 

data sheet pitched roof
sdshzx01-03 (pdf, 250 KB)

Note

The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.

Only for registered members after logging in.
exposed rafter
Cross-section of standard configuration
exposed rafter
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A concrete roof tile or tiled roof 2100 A1
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C 50,0 spruce wood counter battens (Austria: minimum height 50 mm), Germany 30 mm 0,120 50 450 1,600 D
D 22,0 softboard [045; 250] - rigid underlay 0,045 5 250 2,100 E
E 260,0 wood-fibre insulation board [0,040; R=200] - insulation placed on top of the rafters 0,040 5-7 200 2,100 E
F vapour barrier sd≥ 1m 1000
G 40,0 spruce wood tongue and groove, fire protection cladding (Germany minimum 50 mm) 0,120 50 450 1,600 D
H construction timber in acc. with structural design 0,120 50 450 1,600 D

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 83,3 kg
Share of renewable materials of total weight 64,78 %
Global warming potential (GWP-T) -76,384 kgCO2Äqv.
Energy use of Primary Energy 1115,3 MJ
Share of renewable Primary Energy 17,8 %
∑ΔOI3 53,3
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 63,389 -139,773 -76,384 199,035 1432,199 1631,234 916,309 109,597 1025,906 0,238 0,108 4.9413264E-6 0,046

Last update 02.08.2023/hfa.eco2soft