Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 4,0 plaster 1,000 10-35 2000 1,130 A1
B - variable building material
C 12,0 particleboard 0,130 50-100 700 1,700 D
D construction timber (60/..; e=*) 0,120 50 450 1,600 D
E - variable insulation material
F 16,0 particleboard 0,130 50-100 700 1,700 D
G vapour barrier sd≥ 17m 1000
H 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
H 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) OI3Kon m [kg/m²]
awropo07a-00 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
254,5 e=625 60 from inside
30 from outside
0,20 adequate 44 (-2,-6) 4,58 47,3
awropo07a-01 B
D
E
50,0
120,0
120,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
214,5 e=625 60 from inside
30 from outside
0,24 adequate 43 (-2,-6) 2,06 48,8
awropo07a-02 B
D
E
50,0
200,0
200,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
294,5 e=625 60 from inside
30 from outside
0,17 adequate 45 (-2,-6) 7,11 49,8
awropo07a-03 B
D
E
50,0
240,0
240,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
334,5 e=625 60 from inside
30 from outside
0,15 adequate 46 (-2,-6) 9,63 52,3
awropo07a-04 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [035; 50; <1000°C]
254,5 e=625 60 from inside
30 from outside
0,18 adequate 45 (-2,-6) 25,09 52,3
awropo07a-05 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [038; ≥33; ≥1000°C]
254,5 e=625 60 from inside
30 from outside
0,20 adequate 44 (-2,-6) 6,63 49,8
awropo07a-06 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
cellulose fibre [0,040; R=55]
254,5 e=625 60 from inside
30 from outside
0,20 adequate 44 (-2,-6) -0,79 53,0
awropo07a-07 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
sheep wool [0,041; R=26]
254,5 e=625 60 from inside
30 from outside
0,21 adequate 44 (-2,-6) -2,60 47,3
awropo07a-08 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
254,5 e=400 60 from inside
30 from outside
0,21 adequate 44 (-2,-6) 4,25 51,5
awropo07a-09 B
D
E
160,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
364,5 e=625 60 from inside
30 from outside
0,13 adequate 44 (-2,-6) 17,58 49,2
awropo07a-10 B
D
E
50,0
160,0
160,0
Elasticized polystyrene FS
construction timber
mineral wool [040; ≥16; <1000°C]
254,5 e=625 60 from inside
30 from outside
0,20 adequate 47 (-2,-6) 4,58 47,3

Last update 02.03.2017/hfa.plb