Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
compartment wall solid wood construction, without dry lining, double-layer, wooden surface
Fire performance | REI | 60 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/m
Classified by HFA
|
||
Thermal performance | U | 0,39 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 48 dB |
Ln,w (Cl) | ||
Rating by TU-GRAZ
|
||
Mass per unit area | m | 97,0 kg/m2 |
data sheet compartment wall
twmxxo03a-02 (pdf, 250 KB)
Cross laminated timer
Var. 00-01: thickness ≥ 78mm; 3-ply at least, surface layer at least 25mm
Var. 02: thickness ≥ 94,0mm; 3-ply at least, surface layer at least 30mm
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | without gypsum board lining | ||||||
A | without gypsum board lining | ||||||
B | 94,0 | solid glued wood (e.g. cross laminated timber) | 0,130 | 50 | 500 | 1,600 | D |
C | 30,0 | impact sound absorbing subflooring MW-T | 0,035 | 1 | 68 | 1,030 | A1 |
D | 94,0 | solid glued wood (e.g. cross laminated timber) | 0,130 | 50 | 500 | 1,600 | D |
E | without gypsum board lining | ||||||
E | without gypsum board lining |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 43,783 | -137,445 | -93,661 | 52,490 | 1285,920 | 1338,410 | 735,369 | 32,300 | 767,668 | 0,230 | 0,096 | 3.8955845E-6 | 0,071 |
Last update 02.08.2023/hfa.eco2soft