Skip to main content
de
en
Login
Suche
Suchen
Building materials
Beams, columns
Particle composites
Fibre composites
Laminates/panels
Planed wood
Wood flooring and parquet
Insulation
Lining materials
Foils/Barriers/Membranes
Facade solutions
Components
External wall
Internal wall
Compartment wall
Intermediate floor
Floor towards attic
Pitched roof
Flat roof
(current)
You are here:
Components
Flat roof
Flat roof
Regional validity
Scope
All components
Germany
Flachdach/flachgeneigtes Dach
Components
Flachdach/flachgeneigtes Dach
25
Components
Reset
Constrution
+
Construction
Timber frame
Exposed rafter
Solid wood
Roofing
Tile
Metal sheet
Membrane materials
Roof structure
Ventilated
Not ventilated
External planking
MDF
Softboard
Wood cladding
Cavity insulation
Mineral wool <1000°C
Mineral wool ≥1000°C
Cellulose
Sheep wool
Wood fibre
Roof insulation
Mineral wool ≥1000°C
Wood fibre
Polystyrene
Dry lining
With battens
With suspension
Directly
Without
Internal Surface
Wooden
Gypsum plasterboard
Building physics
+
Fire performance
REI30
REI45
REI60
REI60 / K
2
60
REI90
REI90 / K
2
60
Thermal performance
U ≤0,15 W/(m
2
K)
U 0,16–0,20 W/(m
2
K)
U ≥0,21 W/(m
2
K)
Acoustic performance
R
w
≤43 dB
R
w
44–47 dB
R
w
48–57 dB
R
w
≥58 dB
Sustainability
+
Energy use of Primary Energy
<600 MJ/m
2
<700 MJ/m
2
<850 MJ/m
2
<1000 MJ/m
2
∑ΔOI3
<30
<40
<55
<70
GWP-T
<-45 kgCO
2
Äqv.
<-35 kgCO
2
Äqv.
<-25 kgCO
2
Äqv.
<-15 kgCO
2
Äqv.
Built-in renewable materials
>40 %
>60 %
>80 %
Energy use of Primary Energy
<500 MJ/m
2
<700 MJ/m
2
<1000 MJ/m
2
<1200 MJ/m
2
Share of renewable Primary Energy
>10 %
>20 %
>30 %
>40 %
Biogenic carbon
<40 kgCO
2
Äqv.
<70 kgCO
2
Äqv.
<100 kgCO
2
Äqv.
<130 kgCO
2
Äqv.
Built-in renewable materials
>40 kg/m
2
>60 kg/m
2
>80 kg/m
2
Hits for components flat roof
fdmbi01a
3 Variants
fdmnko01
2 Variants
fdmnti01a
2 Variants
fdmobi01a
4 Variants
fdrhbi01a
8 Variants
fdrhbi01b
8 Variants
fdrhbi02a
7 Variants
fdrhbi02b
7 Variants
fdrhbi03a
7 Variants
fdrhbi03b
7 Variants
fdrhbi04a
7 Variants
fdrhbi04b
7 Variants
fdrhbi05a
7 Variants
fdrhbi05b
7 Variants
fdrhbi06a
8 Variants
fdrhbi06b
8 Variants
fdrhbi07a
7 Variants
fdrhbi07b
7 Variants
fdrhbi08a
8 Variants
fdrhbi08b
8 Variants
fdrhbi10a
7 Variants
fdrhbi10b
7 Variants
fdroba01a
3 Variants
fdrobo01a
4 Variants
fdrobo02a
3 Variants
Components
Wall
External wall
Internal wall
Compartment wall
Component ceiling / roof
Intermediate floor
Floor towards attic
Pitched roof
Flat roof
Information about components
Nomenclature