flat roof timber frame construction, ventilated, with dry lining, not suspended
The design of the under-roof construction and of the counter-battens have to be specified according to the roof pitch and the national requirements.
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | sheet metal roofing or plastic roofing membrane | 7800 | A1 | ||||
A | Plastic roofing membrane | E | |||||
B | 24,0 | spruce wood closed cladding without spacing of cladding boards | 0,120 | 50 | 450 | 1,600 | D |
C | 80,0 | spruce wood counter battens (ventilation) | 0,120 | 50 | 450 | 1,600 | D |
D | sarking membrane sd ≤ 0,3m | 1000 | E | ||||
E | 22,0 | softboard [045; 250] - rigid underlay | 0,045 | 5 | 250 | 2,100 | E |
F | construction timber (80/*; e=800) | 0,120 | 50 | 450 | 1,600 | D | |
G | - variable insulation material | ||||||
H | vapour barrier sd≥ 2m | 1000 | |||||
I | 50,0 | spruce wood cross battens (50/80;a=400) | 0,120 | 50 | 450 | 1,600 | D |
J | - variable insulation material or without insulation in type 01 | ||||||
K | 25,0 | gypsum fibre board (2x12,5 mm) or | 0,320 | 21 | 1000 | 1,100 | A2 |
K | 25,0 | gypsum plaster board type DF (2x12,5 mm) | 0,250 | 10 | 800 | 1,050 | A2 |
Thickness of layer | Note | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] |
Last update 02.08.2023/nu.ge