flat roof timber frame construction, not ventilated, without dry lining, directly
ATTENTION: Regarding protection against moisture an object-related proof in terms of paramter like e.g. climate, shading class etc. is required. Therfore a hygrothermic simulation is necessary (e.g.WUFI), a simple Glaser calculation ist not allowed.
| Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
|---|---|---|---|---|---|---|---|
| λ | μ min – max | ρ | c | ||||
| A | Plastic roofing membrane | E | |||||
| B | 25,0 | OSB | 0,130 | 200 | 600 | 1,700 | D |
| C | - variable building material | ||||||
| D | mineral wool [040; 33; ≥1000°C] | 0,040 | 1 | 33 | 1,030 | A1 | |
| E | moisture-adaptive vapour retarder | E | |||||
| F | 32,0 | perforated trapezoidal metal sheet | E | ||||
| Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] | ||
Last update 02.08.2023/nu.ge