Building physical assessment

Fire performance REI 60
maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m  
Classified by MA39  
Thermal performance U 0,25 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 60 dB (-1; -6)
Ln,w (Cl)
Assessed by TGM  
Mass per unit area m 82,4 kg/m2
 
timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 15,0 plaster 0,700 10 1300 1,000 A1
B 50,0 Heraklith BM 0,090 2-5 370 2,000 B
C construction timber (60/100; e=625) 0,120 50 450 1,600 D
D 120,0 Heralan KP 0,040 1 28 1,030 A1
E 50,0 Heraklith BM 0,090 2-5 370 2,000 B
F 15,0 plaster 0,700 10 1300 1,000 A1

Ecological rating (per m2 construction area)

Database ecoinvent

OI3Kon -10,5
Calculated by IBO  

GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
PEI ne
[MJ]
PEI e
[MJ]
EP
[kg PO4 Äqv.]
POCP
[kg C2H4 Äqv.]
1,7 0,103 354,9 348,4 0,013 0,020

Source: Knauf Insulation GmbH

Last update 29.07.2016/hfa.plb