Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside 90
maximum ceiling height = 3 m; maximum load Ed,fi = 70,63 kN/m  
Classified by IBS  
Thermal performance U 0,20 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 45 dB (-2; -7)
Ln,w (Cl)
Assessed by IFT  
Mass per unit area m 93,2 kg/m2
Calculation based on gypsum plaster board type DF GF
 
solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 19,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 40,0 spruce wood battens (40/60) 0,120 50 450 1,600 D
C vapour-permeable membrane sd ≤ 0,3m
D 160,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E 160,0 mineral wool [035; 18] 0,035 1 18 1,030 A1
F 100,0 cross laminated timber BBS 0,130 50 470 1,600 D
G 15,0 gypsum plaster boards Rigips RF or 0,250 10 900 1,050 A2
G gypsum fibre board Rigidur H 0,350 19 1200 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

OI3Kon -5,3
Calculated by IBO  

GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
PEI ne
[MJ]
PEI e
[MJ]
EP
[kg PO4 Äqv.]
POCP
[kg C2H4 Äqv.]
-87,6 0,183 635,7 1.577,0 0,030 0,043

Source: Saint-Gobain Rigips Austria GesmbH

Last update 28.09.2017/hfa.plb