Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/m  
Classified by MA39/HFA  
Fire performance Germany
Classification: REI60 (from inside/from outside)  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,28 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 38 dB (-1; -6)
Ln,w (Cl)
Assessed by Müller-BBM  
Mass per unit area m 83,8 kg/m2
 

Datenblatt external wall
awmopo01a-05 (pdf, 250 KB)

Note

Cross laminated timber:
Variation 00-03: d ≥ 78,0; at least 3-layers, top layer at least 25 mm; variation 04-07: at least 3-layers, top layer at least 30 mm

solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 120,0 wood-fibre insulation board [045; 190] 0,045 5-7 190 2,100 E
C 100,0 solid wood (e.g. cross laminated timber) 0,130 50 500 1,600 D
D without gypsum board lining

Ecological rating (per m2 construction area)

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 73,6 kg
Biogenic carbon 105,8 kgCO2 Äqv.
Energy use of Primary Energy 822,4 MJ
Share of renewable PE 40,1 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -77,514 0,095 0,020 2,46E-6 0,020 328,250 1.082,514 1.408,884 474,997 28,984 503,450
C1 - C4 103,505 0,002 0,000 1,14E-7 0,000 1,201 -1.082,514 -1.081,149 17,917 -21,224 -1,100
A1 - C4 26,671 0,099 0,021 2,57E-6 0,019 329,451 0,000 327,939 492,914 7,760 505,720

Last update 28.08.2018/hfa.plb