Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall timber frame construction, ventilated, with dry lining, with cladding
Fire performance |
REI
from inside
REI from outside |
60
30 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 32 kN/m
Classified by HFA
|
||
Thermal performance | U | 0,19 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 45 dB (-2; -7) |
Ln,w (Cl) | ||
with closed wooden facade Rw von 48 (-3; -10)
Rating by TGM
|
||
Mass per unit area | m | 56,1 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 19,0 | larch wood external wall cladding (open) vertical | 0,155 | 150 | 600 | 1,600 | D |
B | 30,0 | larch wood - cross battens (30/50; 30/80) - ventilation | 0,155 | 150 | 600 | 1,600 | D |
C | wind barrier | 1000 | |||||
D | 15,0 | fibreboard (MDF) | 0,140 | 11 | 600 | 1,700 | D |
E | 160,0 | construction timber (60/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
F | 160,0 | mineral wool [038; ≥33; ≥1000°C] | 0,038 | 1 | 33 | 1,030 | A1 |
G | 15,0 | OSB | 0,130 | 200 | 600 | 1,700 | D |
H | 40,0 | spruce wood cross battens (a=400) or battens offset) | 0,120 | 50 | 450 | 1,600 | D |
I | 40,0 | mineral wool [038; ≥33; ≥1000°C] | 0,038 | 1 | 33 | 1,030 | A1 |
J | 19,0 | planking tongue and groove | 0,120 | 50 | 450 | 1,600 | D |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 32,203 | -82,700 | -50,497 | 89,893 | 831,884 | 921,777 | 441,163 | 38,974 | 480,138 | 0,206 | 0,061 | 1.7308544E-6 | 0,036 |
Last update 02.08.2023/hfa.eco2soft