Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall timber frame construction, not ventilated, without dry lining, with rendering
Fire performance | REI from inside REI from outside |
90 90 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 27 kN/m
Classified by HFA
|
||
Thermal performance | U | 0,14 W/(m2K) |
Diffusion | adequate | |
Calculated by IBO
|
||
Acoustic performance | Rw (C;Ctr) | 44 dB |
Ln,w (Cl) | ||
The acoustic insulation assessment is based on a length-related flow resistance of r≥5 kPa.s/m². If this value is lower for the insulation material used, the Rw value is reduced by 3dB.
Rating by TGM
|
||
Mass per unit area | m | 78,6 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fire | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 7,0 | Plaster „weberpas topdry“ | 0,450 | 10-35 | 1600 | 1,130 | A2 |
B | 140,0 | WF-PT [042; 180] dynamic stiffness s'<15MN/m³. | 0,042 | 3-7 | 180 | 2,100 | E |
C | 15,0 | Rigips Riduro | 0,250 | 4-10 | 1000 | 1,050 | A2 |
D | 160,0 | construction timber (60/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
E | 160,0 | ISOVER Ultimate | 0,035 | 1 | 20 | 1,030 | A1 |
F | vapour barrier sd≥ 6m | 1000 | |||||
G | 15,0 | Rigips Riduro | 0,250 | 4-10 | 1000 | 1,050 | A2 |
ΔOI3 | 47,0 |
---|---|
Calculated by IBO
|
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP [kg CO2 Äqv.] |
AP [kg SO2 Äqv.] |
EP [kg PO4 Äqv.] |
ODP [kg R11 Äqv.] |
POCP [kg Ethen Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
A1 - A3 | -11,300 | 0,182 | 0,082 | 4,03e-6 | 0,025 | 71,600 | 556,000 | 627,600 | 692,000 | 44,500 | 736,500 |
Source: Saint-Gobain Austria GmbH
Last update 06.08.2020/hfa.plb