intermediate floor exposed beams, without lining, dry, with filling
Fire performance | REI | 30 |
---|---|---|
maximum span = 5 m; maximum load Ed,fi = 5,29 kN/m²
Classified by HFA
|
||
Thermal performance | U | 0,39 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 56 dB (-4; -10) |
Ln,w (Cl) | 59 dB (2) | |
Rating by TGM
|
||
Mass per unit area | m | 107,6 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | spruce wood 3-strip parquet | 0,120 | 50 | 450 | 1,600 | D | |
B | 50,0 | spruce wood sleeper (50/80; e=600) | 0,120 | 50 | 450 | 1,600 | D |
C | 50,0 | mineral wool [040; ≥16; <1000°C] | 0,040 | 1 | 16 | 1,030 | A1 |
D | 30,0 | impact sound absorbing subflooring MW-T | 0,035 | 1 | 68 | 1,030 | A1 |
E | 40,0 | fill | 0,700 | 1 | 1800 | 1,000 | A1 |
F | trickling protection | E | |||||
G | 40,0 | planking spruce wood | 0,120 | 50 | 450 | 1,600 | D |
H | construction timber floor joists (in acc. with structural design) | 0,120 | 50 | 450 | 1,600 | D |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 17,352 | -71,318 | -53,966 | 138,559 | 744,107 | 882,666 | 308,279 | 3,822 | 312,102 | 0,106 | 0,048 | 1.6567315E-6 | 0,028 |