Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 60
maximum span = 4 m; maximum load Ed,fi = 7,92 kN/m²  
Classified by IBS  
Thermal performance U 0,12 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 61 dB (-5; -12)
Ln,w (Cl)
Assessed by IFT  
Mass per unit area m 169,7 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A concrete roof tile /tiled roof 2100 A1
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C 50,0 spruce wood counter battens (minimum height 50 mm) 0,120 50 450 1,600 D
D sarking membrane sd ≤ 0,3m 1000 E
E 200,0 ? insulation placed on top of the rafters 0,035 1 100 1,030 A2
F sealing sheet
G 100,0 cross laminated timber BBS 5 layer 0,130 50 470 1,600 D
H 70,0 spruce wood battens (60/60; e=625) mounted on resilient clips 0,120 50 450 1,600 D
I 50,0 mineral wool [040; 18] 0,040 1 18 1,030 A1
J 15,0 gypsum plaster boards Rigips RF or 0,250 10 900 1,050 A2
J 15,0 gypsum fibre board Rigidur H 0,350 19 1200 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

OI3Kon 20,5
Calculated by IBO  

GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
PEI ne
[MJ]
PEI e
[MJ]
EP
[kg PO4 Äqv.]
POCP
[kg C2H4 Äqv.]
-86,5 0,223 1,246,5 1.872,1 0,032 0,069

Source: Saint-Gobain Rigips Austria GesmbH

Last update 28.09.2017/hfa.plb