Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
pitched roof timber frame construction, ventilated, with dry lining, directly
Fire performance | REI | 60 |
---|---|---|
maximum span = 5 m; maximum load Ed,fi = 1,32 kN/m²
Classified by HFA
|
||
Thermal performance | U | 0,22 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 51 dB (-3; -9) |
Ln,w (Cl) | ||
Rating by TGM
|
||
Mass per unit area | m | 102,6 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | concrete roof tile or tiled roof | 2100 | A1 | ||||
B | 30,0 | spruce wood battens (30/50) | 0,120 | 50 | 450 | 1,600 | D |
C | 50,0 | spruce wood battens (min. 50 mm) | 0,120 | 50 | 450 | 1,600 | D |
D | sarking membrane sd ≤ 0,3m | 1000 | E | ||||
E | 24,0 | planking spruce wood closed cladding without spacing of cladding boards | 0,120 | 50 | 450 | 1,600 | D |
F | 160,0 | construction timber (80/..; e=800) | 0,120 | 50 | 450 | 1,600 | D |
G | 160,0 | glass wool UNIFIT [037; R=14] | 0,037 | 1 | 14 | 1,030 | A1 |
H | vapour barrier sd≥ 6m | 1000 | |||||
I | 50,0 | Heraklith BM | 0,090 | 2-5 | 370 | 2,000 | B |
J | 10,0 | plaster | 0,700 | 10 | 1300 | 1,000 | A1 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 34,081 | -51,386 | -17,305 | 93,422 | 518,400 | 611,821 | 445,462 | 10,862 | 456,324 | 0,122 | 0,055 | 2.895011E-6 | 0,024 |
Source: Knauf Insulation GmbH
Last update 02.08.2023/hfa.eco2soft