Building physical assessment

Fire performance REI 60
maximum span = 5 m; maximum load Ed,fi = 1,32 kN/m²  
Classified by HFA  
Thermal performance U 0,18 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 51 dB (-3; -9)
Ln,w (Cl)
Assessed by TGM  
Mass per unit area m 107,8 kg/m2
 
timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A concrete roof tile or tiled roof 2100 A1
B 30,0 spruce wood battens (30/50) 0,120 50 450 1,600 D
C 50,0 spruce wood battens (min. 50 mm) 0,120 50 450 1,600 D
D sarking membrane sd ≤ 0,3m 1000 E
E 24,0 planking spruce wood closed cladding without spacing of cladding boards 0,120 50 450 1,600 D
F 200,0 construction timber (80/..; e=800) 0,120 50 450 1,600 D
G 200,0 mineral wool Klemmplatte KP [038; R=30] 0,038 1 30 1,030 A1
H vapour barrier sd≥ 6m 1000
I 50,0 Heraklith BM 0,090 2-5 370 2,000 B
J 10,0 plaster 0,700 10 1300 1,000 A1

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 32,7
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -15,363 0,159 0,059 2,70e-6 0,030 124,770 459,537 584,307 411,145 11,194 422,339

Source: Knauf Insulation GmbH

Last update 07.05.2020/hfa.plb