compartment wall solid wood construction, without dry lining, double-layer, other surface
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 36,0 | gypsum plaster board type DF (2x18 mm) or | 0,250 | 10 | 800 | 1,050 | A2 |
A | 36,0 | gypsum fibre board (2x18 mm) | 0,320 | 21 | 1000 | 1,100 | A2 |
B | 80,0 | cross laminated timber | 0,130 | 50 | 500 | 1,600 | D |
C | impact sound absorbing subflooring MW-T | 0,035 | 1 | 68 | 1,030 | A1 | |
D | 80,0 | cross laminated timber | 0,130 | 50 | 500 | 1,600 | D |
G | 36,0 | gypsum plaster board type DF (2x18 mm) or | 0,250 | 10 | 800 | 1,050 | A2 |
G | 36,0 | gypsum fibre board (2x18 mm) | 0,320 | 21 | 1000 | 1,100 | A2 |
Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] |
Last update 28.06.2018/hfa.plb