Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
compartment wall solid wood construction, without dry lining, single-layer, other surface
Fire performance | REI | 90 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/m
Classified by MA39
|
||
Thermal performance | U | 0,33 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 60 dB (-3; -9) |
Ln,w (Cl) | ||
Rating by TGM
|
||
Mass per unit area | m | 165,4 kg/m2 |
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 15,0 | plaster | 0,700 | 10 | 1300 | 1,000 | A1 |
B | 50,0 | Heraklith BM | 0,090 | 2-5 | 370 | 2,000 | B |
C | 140,0 | solid glued wood | 0,130 | 50 | 500 | 1,600 | D |
D | 20,0 | Heralan TP 25/20 | 0,035 | 1 | 105 | 1,030 | A1 |
E | 50,0 | Heraklith BM | 0,090 | 2-5 | 370 | 2,000 | B |
F | 15,0 | plaster | 0,700 | 10 | 1300 | 1,000 | A1 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 55,602 | -124,898 | -69,296 | 70,470 | 1157,688 | 1228,158 | 739,346 | 24,053 | 763,398 | 0,221 | 0,084 | 4.0262108E-6 | 0,067 |
Source: Knauf Insulation GmbH
Last update 02.08.2023/hfa.eco2soft