external wall solid wood construction, ventilated, with dry lining, with cladding
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 19,0 | larch wood external wall cladding | 0,155 | 150 | 600 | 1,600 | D |
B | 40,0 | spruce wood battens (40/60) | 0,120 | 50 | 450 | 1,600 | D |
C | vapour-permeable membrane sd ≤ 0,3m | ||||||
D | construction timber 60/..; e=625 | 0,120 | 50 | 450 | 1,600 | D | |
E | mineral wool [035; 18; <1000°C] | 0,035 | 1 | 18 | 1,030 | A1 | |
F | cross laminated timber BBS 125 | 0,130 | 50 | 470 | 1,600 | D | |
G | 70,0 | spruce wood battens (60/60; e=625) mounted on resilient clips | 0,120 | 50 | 450 | 1,600 | D |
H | 50,0 | mineral wool [040; 18; <1000°C] | 0,040 | 1 | 18 | 1,030 | A1 |
I | 25,0 | gypsum plaster boards Rigips RF (2x12,5 mm) or | 0,250 | 10 | 900 | 1,050 | A2 |
I | 25,0 | gypsum fibre board Rigidur H (2x12,5 mm) | 0,350 | 19 | 1200 | 1,100 | A2 |
Thickness of layer | Note | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] |
Source: Saint-Gobain Austria GmbH
Last update 01.02.2024/hfa.plb