external wall timber frame construction, ventilated, with dry lining, with cladding
Thickness [mm] | Building material | Thermal performance | Reaction to fire | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 24,0 | larch wood external wall cladding | 0,155 | 150 | 600 | 1,600 | D |
B | 30,0 | spruce wood battens offset (30/50; 30/80) - ventilation | 0,120 | 50 | 450 | 1,600 | D |
C | wind barrier | 1000 | |||||
D | 12,5 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
E | construction timber (60/..; e=625) | 0,120 | 50 | 450 | 1,600 | D | |
F | - variable insulation material | ||||||
G | vapour barrier sd≥ 5m | 1000 | |||||
H | 12,5 | gypsum plaster board type DF | 0,250 | 10 | 800 | 1,050 | A2 |
I | spruce wood cross battens (a=400) ≥ 40mm | 0,120 | 50 | 450 | 1,600 | D | |
J | - variable insulation material ≥40mm | ||||||
K | 12,5 | gypsum plaster board type A | 0,250 | 4-10 | 680 | 1,050 | A2 |
Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) | ΔOI3 | m [kg/m²] | ||
awrhhi11a-00 | E F I J |
160,0 160,0 40,0 40,0 |
construction timber (60/..; e=625) mineral wool [040; 30; ≥1000°C] spruce wood cross battens (a=400) ≥ 40mm mineral wool [040; 30; ≥1000°C] |
294,0 | 60 from inside 60 from outside |
0,21 | adequate | 58 (-1,-6) | 28,67 | 60,6 |
awrhhi11a-01 | E F I J |
160,0 160,0 40,0 40,0 |
construction timber (60/..; e=625) Cellulose fibre [040; 50] spruce wood cross battens (a=400) ≥ 40mm Cellulose fibre [040; 50] |
291,5 | 30 from inside 30 from outside |
0,21 | adequate | 58 (-1,-6) | 18,39 | 64,2 |
awrhhi11a-02 | E F I J |
160,0 160,0 40,0 40,0 |
construction timber (60/..; e=625) Wood fibre insulation [039; 45] spruce wood cross battens (a=400) ≥ 40mm Wood fibre insulation [039; 45] |
294,0 | 30 from inside 30 from outside |
0,21 | adequate | 58 (-1,-6) | 20,88 | 63,3 |
awrhhi11a-03 | E F I J |
200,0 200,0 40,0 40,0 |
construction timber (60/..; e=625) mineral wool [040; 30; ≥1000°C] spruce wood cross battens (a=400) ≥ 40mm mineral wool [040; 30; ≥1000°C] |
334,0 | 60 from inside 60 from outside |
0,18 | adequate | 59 (-1,-6) | 31,93 | 63,4 |
awrhhi11a-04 | E F I J |
200,0 200,0 40,0 40,0 |
construction timber (60/..; e=625) Cellulose fibre [040; 50] spruce wood cross battens (a=400) ≥ 40mm Cellulose fibre [040; 50] |
331,5 | 30 from inside 30 from outside |
0,18 | adequate | 59 (-1,-6) | 19,57 | 67,8 |
awrhhi11a-05 | E F I J |
200,0 200,0 40,0 40,0 |
construction timber (60/..; e=625) Wood fibre insulation [039; 45] spruce wood cross battens (a=400) ≥ 40mm Wood fibre insulation [039; 45] |
334,0 | 30 from inside 30 from outside |
0,18 | adequate | 59 (-1,-6) | 22,57 | 66,7 |
awrhhi11a-06 | E F I J |
240,0 240,0 40,0 40,0 |
construction timber (60/..; e=625) mineral wool [040; 30; ≥1000°C] spruce wood cross battens (a=400) ≥ 40mm mineral wool [040; 30; ≥1000°C] |
374,0 | 60 from inside 60 from outside |
0,16 | adequate | 60 (-1,-6) | 35,19 | 66,2 |
awrhhi11a-07 | E F I J |
240,0 240,0 40,0 40,0 |
construction timber (60/..; e=625) Cellulose fibre [040; 50] spruce wood cross battens (a=400) ≥ 40mm Cellulose fibre [040; 50] |
371,5 | 30 from inside 30 from outside |
0,16 | adequate | 60 (-1,-6) | 20,74 | 71,3 |
awrhhi11a-08 | E F I J |
240,0 240,0 40,0 40,0 |
construction timber (60/..; e=625) Wood fibre insulation [039; 45] spruce wood cross battens (a=400) ≥ 40mm Wood fibre insulation [039; 45] |
374,0 | 30 from inside 30 from outside |
0,16 | adequate | 60 (-1,-6) | 24,25 | 70,0 |
Last update 07.05.2020/hfa.plb