Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 50,0 spruce wood cross battens 0,120 50 450 1,600 D
C 40,0 softboard [045; 250] - rigid underlay 0,045 5 250 2,100 E
D 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
E construction timber (60/..; e=*) 0,120 50 450 1,600 D
F - variable insulation material
G 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
H spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
I - variable insulation material or air layer in type 02
J 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
J 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awrohi02a-00 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
316,5 e=625 60 from inside
30 from outside
0,17 adequate 50 (-3,-9) 30,43 63,5
awrohi02a-01 E
F
H
I
120,0
120,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
276,5 e=625 60 from inside
30 from outside
0,20 adequate 49 (-3,-9) 27,79 62,0
awrohi02a-02 E
F
H
I
160,0
160,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
nur Lattung
316,5 e=625; I=without insulation 60 from inside
30 from outside
0,19 adequate 49 (-3,-9) 28,03 64,0
awrohi02a-03 E
F
H
I
200,0
200,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
356,5 e=625 60 from inside
30 from outside
0,15 adequate 51 (-3,-9) 33,08 67,0
awrohi02a-04 E
F
H
I
240,0
240,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
396,5 e=625 60 from inside
30 from outside
0,13 adequate 52 (-3,-9) 35,72 69,5
awrohi02a-05 E
F
H
I
200,0
200,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
396,5 e=625 60 from inside
30 from outside
0,13 adequate 51 (-3,-9) 35,36 70,1
awrohi02a-06 E
F
H
I
240,0
240,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
436,5 e=625 60 from inside
30 from outside
0,12 adequate 52 (-3,-9) 38,01 72,6
awrohi02a-07 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
316,5 e=625 60 from inside
30 from outside
0,16 adequate 51 (-3,-9) 52,86 71,7
awrohi02a-08 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
316,5 e=625 60 from inside
30 from outside
0,17 adequate 50 (-3,-9) 36,22 67,6
awrohi02a-09 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
cellulose fibre [040; E]
spruce wood
cellulose fibre [040; E]
316,5 e=625 60 from inside
30 from outside
0,17 adequate 50 (-3,-9) 23,60 71,5
awrohi02a-10 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
316,5 e=625 60 from inside
30 from outside
0,19 adequate 50 (-3,-9) 24,41 64,5
awrohi02a-11 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
316,5 e=400 60 from inside
30 from outside
0,18 adequate 50 (-3,-9) 30,03 69,1

Last update 02.08.2023/hfa.eco2soft