external wall timber frame construction, not ventilated, with dry lining, with rendering
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 7,0 | plaster | 1,000 | 10-35 | 2000 | 1,130 | A1 |
B | 60,0 | wood-fibre insulation board [045; 190] | 0,045 | 5-7 | 190 | 2,100 | E |
C | 300,0 | Light composite wood-based beams (I-beams) with solid wood flanges (60/45) and hard board intermediate web (≥ 6,7) e=625 | 0,400 | 20-30 | 800 | 1,700 | D |
D | - variable insulation material | ||||||
E | 15,0 | OSB | 0,130 | 200 | 600 | 1,700 | D |
F | 80,0 | spruce wood battens on resilient clips (50/80; e=625) | 0,120 | 50 | 450 | 1,600 | D |
G | - variable insulation material | ||||||
H | 15,0 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
H | 15,0 | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 |
Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] |
Last update 02.08.2023/hfa.eco2soft