Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
90
60
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/m  
Classified by MA39/HFA  
Thermal performance U 0,25 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 50 dB
Ln,w (Cl)
Rw+Ctr ≥ 42
Assessed by TU-GRAZ  
Mass per unit area m 108,7 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

Datenblatt external wall
awmopi01a-05 (pdf, 250 KB)

Note

Attention: REI90 (from inside) in Germany possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board

solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 15,0 plaster 1,000 10-35 2000 1,130 A1
B 100,0 multilayer wood wool composite board (WW-MW-WW) ETICS insulation panel 0,049 2-5 130 1,000 B
C 97,0 cross laminated timber 0,130 50 500 1,600 D
D 70,0 spruce wood battens (60/60) mounted on resilient clips; e=660 0,120 50 450 1,600 D
E 50,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
F 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
F 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

OI3Kon 39,2
Calculated by HFA  

GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
PEI ne
[MJ]
PEI e
[MJ]
EP
[kg PO4 Äqv.]
POCP
[kg C2H4 Äqv.]
-27,5 0,340 1,040,9 1.123,5 0,049 0,062

Last update 28.08.2018/hfa.plb