Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
90
60
maximum ceiling height = 3 m; maximum load Ed,fi = 35 kN/m  
Classified by HFA  
Fire performance Germany
Classification: REI 60 (from inside/from outside); Attention: REI 90 (from inside) possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,15 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 56 dB (-3; -9)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 97,3 kg/m2
Calculation based on gypsum plaster board type DF GKF
 

data sheet external wall
awmopi05a-00 (pdf, 250 KB)

Note

Attention: REI 90 (from inside) in Germany possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board

Only for registered members after logging in.
solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board [046; 200] 0,046 3-7 200 2,100 E
C 160,0 construction timber (60/160; e=625) 0,120 50 450 1,600 D
D 160,0 mineral wool [040; 11; <1000°C] 0,040 1 11 1,030 A1
E 100,0 cross laminated timber 0,130 50 500 1,600 D
F 50,0 spruce wood battens horizontal ≥50 0,120 50 450 1,600 D
G 50,0 mineral wool [040; 11; <1000°C] ≥50 0,040 1 11 1,030 A1
H 15,0 gypsum fibre board or 0,320 21 1000 1,100 A2
H 15,0 gypsum plaster board type DF 0,250 10 800 1,050 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 66,8 kg
Share of renewable materials of total weight 70,96 %
Global warming potential (GWP-T) -62,577 kgCO2Äqv.
Energy use of Primary Energy 803,0 MJ
Share of renewable Primary Energy 10,3 %
∑ΔOI3 42,8
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 43,594 -106,171 -62,577 83,099 1019,663 1102,763 719,911 34,445 754,356 0,211 0,091 3.9990228E-6 0,051

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 73,2 kg
Biogenic carbon 105,5 kgCO2Äqv.
Energy use of Primary Energy 915,6 MJ
Share of renewable Primary Energy 36,3 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -78,212 0,148 0,027 3.07E-6 0,022 330,806 1168,135 1497,345 554,420 29,461 583,410
C1 - C4 112,498 0,004 0,003 1.73E-7 0,001 1,079 -1161,801 -1160,558 21,062 -10,692 12,580
A1 - C4 37,593 0,156 0,030 3.25E-6 0,023 332,370 6,593 337,736 583,203 18,833 607,140

Last update 02.08.2023/hfa.eco2soft