Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall solid wood construction, not ventilated, without dry lining, with rendering
Fire performance |
REI
from inside
REI from outside |
60
90 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 35,0 kN/m
Classified by HFA
|
||
Thermal performance | U | 0,23 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 39 dB (-1; -4) |
Ln,w (Cl) | ||
Assessed by TU-GRAZ
|
||
Mass per unit area | m | 84,7 kg/m2 |
data sheet external wall
awmopo01a-01 (pdf, 250 KB)
Cross laminated timber:
Variation 00-03: d ≥ 78,0; at least 3-layers, top layer at least 25 mm; variation 04-07: at least 3-layers, top layer at least 30 mm
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 7,0 | plaster | 1,000 | 10-35 | 2000 | 1,130 | A1 |
B | 140,0 | mineral wool MW-PT [040; 155] | 0,040 | 1 | 155 | 1,030 | A1 |
C | 80,0 | solid glued wood (e.g. cross laminated timber) | 0,130 | 50 | 500 | 1,600 | D |
D | 12,5 | gypsum plaster board type DF / gypsum fibre board | 0,250 | 10 | 800 | 1,050 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 58,861 | -57,330 | 1,531 | 41,804 | 533,520 | 575,324 | 817,604 | 13,934 | 831,538 | 0,356 | 0,111 | 3.6018189E-6 | 0,136 |