Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside
REI from outside
60
60
maximum ceiling height = 3 m; maximum load Ed,fi = 32,0 kN/m
Classified by MA39  
Classified by HFA  
Fire performance Germany
Classification: F60 (from inside/from outside)  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,17 W/(m2K)
Diffusion adequate
Calculated by HFA  
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 52 dB (-3; -11)
Ln,w (Cl)
vertical battens for the dry lining screwed onto the structural timber lead to an Rw(C;Ctr)=50(-3;-11) dB
Assessed by MA39  
Rating by Müller-BBM  
Mass per unit area m 57,4 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board WF-PT [045; 180] 0,045 5-7 180 2,100 E
C 160,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
D 160,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
E 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
F 40,0 spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
G 40,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
H 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
H 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 32,8 kg
Share of renewable materials of total weight 55,11 %
Global warming potential (GWP-T) -21,513 kgCO2Äqv.
Energy use of Primary Energy 651,7 MJ
Share of renewable Primary Energy 14,9 %
∑ΔOI3 37,0
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 33,217 -54,730 -21,513 97,401 559,248 656,649 554,336 34,613 588,948 0,157 0,070 3.1083486E-6 0,024

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 34,7 kg
Biogenic carbon 51,1 kgCO2Äqv.
Energy use of Primary Energy 597,9 MJ
Share of renewable Primary Energy 29,8 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -25,984 0,111 0,018 6.94E-7 0,020 176,909 519,574 696,828 400,938 28,204 429,220
C1 - C4 50,151 0,003 0,002 5.25E-8 0,001 0,995 -513,240 -512,082 12,292 -17,012 -2,510
A1 - C4 27,380 0,118 0,022 7.56E-7 0,021 178,291 6,593 185,596 419,588 11,243 436,480

Last update 02.08.2023/hfa.eco2soft