Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
flat roof solid wood construction, not ventilated, with dry lining, suspended
| Fire performance | REI | 60 |
|---|---|---|
|
maximum span = 5 m; maximum load Ed,fi = 0,6 kN/m²
Classified by HFA
|
||
| Thermal performance | U | 0,09 W/(m2K) |
| Diffusion | adequate | |
|
Calculated by HFA
|
||
| Acoustic performance | Rw (C;Ctr) | 48 dB |
| Ln,w (Cl) | ||
|
Rating by HFA
|
||
| Mass per unit area | m | 117,6 kg/m2 |
|
Calculation based on gypsum plaster board type DF GKF
|
||
| Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
|---|---|---|---|---|---|---|---|
| λ | μ min – max | ρ | c | ||||
| A | Plastic roofing membrane | E | |||||
| B | 300,0 | mineral wool [040; 130; ≥1000°C] ; pressure-resistant | 0,040 | 1 | 130 | 1,030 | A1 |
| C | sealing sheet | ||||||
| D | 125,0 | solid glued wood ≥ 125,0; at least 5-layers, top layer at least 27,5 mm | 0,130 | 50 | 500 | 1,600 | D |
| E | 80,0 | spruce wood ; battens on resilient clips (50/80; e=625) | 0,120 | 50 | 450 | 1,600 | D |
| F | 80,0 | mineral wool [040; 18] | 0,040 | 1 | 18 | 1,030 | A1 |
| G | 19,0 | 3-ply solid wood panel | 0,110 | 50 | 400 | 2,500 | D |
| Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
| A1 - A3 | 110,103 | -110,205 | -0,102 | 85,074 | 1061,294 | 1146,368 | 1563,815 | 201,425 | 1765,240 | 0,684 | 0,213 | 8.3129866E-6 | 0,264 |
Last update 02.08.2023/nu.ge