Skip to main content
Regional validity

Scope

solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from top to bottom)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A - variable insulation material
B membrane (airtight)
C 140,0 cross laminated timber 0,130 50 500 1,600 D

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
ddmxxn01-00 A 300,0 mineral wool [040; 130] 440,0 60 0,11 adequate 44 (-2,-7) 124,15 106,0
ddmxxn01-01 A 300,0 wood-fibre insulation board [0,045; R=160] 440,0 60 0,11 adequate 44 (-2,-7) 68,17 110,5

Last update 02.08.2023/hfa.eco2soft